Heating cables for outdoor surface

						
It is possible to protect any area used for passage with the help of heating cables – pavements, paths, drive-up ramps, staircases etc. Special heating cables are used for these applications – robust structures with stranded resistance and wattages of 20-40 W/m.
Ice and snow melting – Installation
Ice and snow melting – Installation

The heating can be provided by a heating circuit as well as a heating mat. For thoroughfares which are walked on, the heating element is placed in a sand bed or into a concrete slab, while in the case of stairs, terraces and similar areas the element is embedded into bonding cement. In thoroughfares used for driving, we unambiguously recommend that the heating element is placed into a concrete slab which will protect the heating cable from damage when the thoroughfare is used by a car. For thoroughfares which aren’t used by vehicles (pavements), the heating cable can only be placed into a sand bedFor the heating of outdoor surfaces a wattage of 300-400 W/m² is installed. Such a high output is necessary for the system to function correctly even at temperatures far below freezing point. Also, correct regulation is very important – see the chapter Regulation of ECOFLOOR heating systems – as it will bring the heating system into operation as soon as there is a danger of ice formation. This means a regulation system which registers not only the temperature but also the presence of moisture in the area monitored. If the system is controlled manually by the user and is brought into operation at a time when the surface concerned has already been covered with a layer of snow, this snow can take more than 12 hours to melt (depending on the height of the layer of snow). It is necessary to realize that the heating cable is placed in the ground, which has a great ability to absorb heat, and also that a large amount of energy is needed for the transformation of snow into water – so called latent heat. The installation of supplementary thermal insulation into the base composition is inefficient with a few exceptions.

For these applications we offer robust MAPSV, MADPSP and PDSP cables with protective sheathing. Another interesting suitable application is the heating of football pitches. MADPSP cables can also be installed in asphalt.

Ice and snow melting – Installation
Ice and snow melting – Stairs
MAPSV Cable construction
MADPSP Cable construction
Football Pitch
Pavement
Accessories – CableFix
Ice and snow melting
Ice and snow melting
Ice and snow melting
Ice and snow melting
Ice and snow melting

MAPSV 30 W/m

Type MAPSV 30 W/m Output Length Cat. No.
[W] [m]
MAPSV 30420 420 14.0 2322600
MAPSV 30500 500 16.3 2322602
MAPSV 30700 700 23.6 2322604
MAPSV 301100 1100 35.6 2322606
MAPSV 301250 1250 42.3 2322608
MAPSV 301600 1600 55.1 2322610
MAPSV 302100 2100 70.0 2322612
MAPSV 302500 2500 84.6 2322614
MAPSV 302950 2950 98.0 2322616
MAPSV 303200 3200 106.7 2322618
MAPSV 304000 4000 134.9 2322620
MAPSV 304800 4800 162.1 2322622
MAPSV 306300 6300 209.9 2322624

ADPSV 30 W/m

Type ADPSV 30 W/m Output Length Cat. No.
[W] [m]
ADPSV 30195 195 7.0 2253505
ADPSV 30340 340 11.0 2253510
ADPSV 30420 420 14.0 2253515
ADPSV 30560 560 18.0 2253520
ADPSV 30670 670 22.0 2253525
ADPSV 30800 800 26.0 2253530
ADPSV 30970 970 32.0 2253535
ADPSV 301060 1060 36.0 2253540
ADPSV 301300 1300 44.0 2253545
ADPSV 301600 1600 52.0 2253550
ADPSV 301940 1940 65.0 2253555
ADPSV 302250 2250 76.0 2253560
ADPSV 302800 2800 96.0 2253565
ADPSV 303400 3400 114.0 2253570

MADPSP 40 W/m

Type MADPSP 40 W/m Output Length Cat. No.
[W] [m]
MADPSP 40340 340 8.5 2323505
MADPSP 40570 570 14.5 2323510
MADPSP 40880 880 22.0 2323515
MADPSP 401030 1030 26.0 2323520
MADPSP 401320 1320 33.0 2323525
MADPSP 401700 1700 43.0 2323530
MADPSP 401880 1880 47.0 2323535
MADPSP 402450 2450 60.0 2323540
MADPSP 402900 2900 73.0 2323545
MADPSP 403400 3400 85.0 2323550
MADPSP 405200 5200 127.0 2323555
MADPSP 407350 7350 180.0 2323560

MADPSP 40 W/m - 400V

Type MADPSP 40 W/m - 400V Output Length Cat. No.
[W] [m]
MADPSP 40600 600 15.0 2323605
MADPSP 401000 1000 25.0 2323610
MADPSP 401520 1520 39.0 2323615
MADPSP 401800 1800 45.0 2323620
MADPSP 402300 2300 58.0 2323625
MADPSP 402970 2970 75.0 2323630
MADPSP 403300 3300 81.0 2323635
MADPSP 404250 4250 105.0 2323640
MADPSP 405100 5100 126.0 2323645
MADPSP 405900 5900 148.0 2323650
MADPSP 409000 9000 222.0 2323655

ECOFLOOR accesories

Type Description Quantity supplied Cat. No.
Gutter clip 100 1 package = 25 pcs 1 package 2350000
Gutter clip 150 1 package = 25 pcs 1 package 2350007
Downpipe cable clip 1 package = 25 pcs 1 package 2350003
Chain 1 package = 10 m 1 package 2350004
Grufast 1 unit = 10 m / 4.5 m2 1 unit 4200013
Cable Fix 1 unit = 10 m 1 unit 4200016
Copper end piece intended as an end piece for a flexible tube ('gooseneck'): outer diameter 11.4 mm / inner diameter 8.5mm – used to prevent sealant (anhydrite, concrete) from entering the gooseneck containing the floor probe and to improve the transfer of heat to the thermistor of the probe = more precise measurement of floor temperatures 1 unit 2350021
Raster separation film 1 unit = 50 m 1 unit 6651032
Plastic cable clip 1 package = 600 pcs 1 package 1200003
Plastic clip 1 package = 50 pcs 1 package 1200000
Installation tool for the comfortable installation of plastic clips 1 unit 1200010
T-strip 1 package = 20 pcs 1 package 2350009
Kit no. 1 for PV cable repair 1 kit 5030121
Kit no. 2 for ADSV, ASL1P, PSV, CM Mat LD and LDTS cable repair 1 kit 5030122
Kit no. 3 for MADPSP, MAPSV, MST, MDT and ADPSV cable and mat repair 1 kit 5030123
Kit no. 4 for connection and termination of self-limiting cables 1 kit 5030124
Kit no. 5 for MADPSP installed under asphalt 1 kit 5030125
Kit no. 6 termination of PC/PC-S cables 1 kit 5030126
Aluminium tape width 50 mm, length 50 m 1 pcs 2832515
SYFOK-P 1 package = 20 m 1 package 2350012
1 package = 10 m 1 package 2350013
Spacing grip 1 package = 25 pcs 1 package 2350014
C-shaped copper 1 package = 25 pcs 1 package 2350005
TOPlist